Technical Specifications
Typical Applications
- Dimensionally stable outdoor parts under UV load
- Housings and brackets on machines in the open
- Large-area ASA parts that would otherwise warp
- Vehicle and add-on parts exposed to weather
Documents will be provided once a specific material is selected.
Material profile
ASA is the standard for parts that live outdoors: UV stable, weather resistant, colour fast. Its weakness is warping across large areas. That is exactly where the carbon fiber comes in.
With 8 % short carbon fiber the tensile modulus rises from around 1,900 to 3,612 MPa, and the part stays flat as it cools. Heat deflection is 103 °C (HDT/A) and drops only to 97.3 °C at 1.8 MPa load – an unusually small gap that speaks for a stable matrix.
Values from the manufacturer datasheet
| Property | X-Y | Z | Test standard |
|---|---|---|---|
| Tensile strength | 43.5 MPa | 25.0 MPa | ISO 527 |
| Tensile modulus | 3,612 MPa | 1,904 MPa | ISO 527 |
| Elongation at break | 1.8 % | 2.7 % | ISO 527 |
| Flexural strength | 69.1 MPa | 46.5 MPa | ISO 178 |
| Flexural modulus | 3,265 MPa | 1,743 MPa | ISO 178 |
| Charpy notched | 5.5 kJ/m² | ISO 179 | |
| HDT/A (0.45 MPa) | 103.0 °C | ISO 75 | |
| HDT (1.8 MPa) | 97.3 °C | ISO 75 | |
| Vicat | 110.8 °C | ISO 306 | |
| Density | 1.09 g/cm³ | ISO 1183 | |
| Surface resistivity | > 10¹² Ω | ANSI ESD S11.11 |
Notable: despite the carbon fiber, surface resistivity is above 10¹² Ω, so the material is insulating. That rules it out for ESD requirements – but makes it uncritical near electronics.
Processing
Nozzle 260–280 °C, bed 90–100 °C, fan off, enclosed chamber recommended. Pre-drying 6 hours at 90 °C, storage below 20 % relative humidity. The manufacturer warns explicitly: a brass nozzle is worn out after about 9 hours. We run this material exclusively with a hardened nozzle from 0.4 mm.